CTIOUTEN<n>, CTI Input Channel to Output Trigger Enable registers, n = 0 - 31

The CTIOUTEN<n> characteristics are:

Purpose

Defines which input channels generate output trigger n.

Configuration

CTIOUTEN<n> is in the Debug power domain.

If output trigger n is not implemented or not connected, CTIOUTEN<n> is RES0.

Attributes

CTIOUTEN<n> is a 32-bit register.

Field descriptions

313029282726252423222120191817161514131211109876543210
OUTEN31OUTEN30OUTEN29OUTEN28OUTEN27OUTEN26OUTEN25OUTEN24OUTEN23OUTEN22OUTEN21OUTEN20OUTEN19OUTEN18OUTEN17OUTEN16OUTEN15OUTEN14OUTEN13OUTEN12OUTEN11OUTEN10OUTEN9OUTEN8OUTEN7OUTEN6OUTEN5OUTEN4OUTEN3OUTEN2OUTEN1OUTEN0

OUTEN<x>, bit [x], for x = 31 to 0

Input channel <x> to output trigger <n> enable.

OUTEN<x>Meaning
0b0

An event on input channel <x> will not cause output trigger <n> to be asserted.

0b1

An event on input channel <x> will cause output trigger <n> to be asserted.

The reset behavior of this field is:

Accessing this field has the following behavior:

Accessing CTIOUTEN<n>

CTIOUTEN<n> can be accessed through the external debug interface:

ComponentOffsetInstance
CTI0x0A0 + (4 * n)CTIOUTEN<n>

Accessible as follows:


21/03/2025 17:53; 154105dd5041532b480d9ef0c018b8420cbe5c19

Copyright © 2010-2025 Arm Limited or its affiliates. All rights reserved. This document is Non-Confidential.